Set Neurolab Complete 31/37
Set Neurolab Complete 31/37

Set Neurolab Complete 31/37

Item No.: A001122
The "NEUROLAB COMPLETE 31/37" set is a comprehensive, state-of-the-art and highly precise EEG/ERP recording and neurofeedback training solution, which can be used in manifold areas of EEG-/ERP-based diagnostics, biomarker development and neurofeedback in research and therapeutic practice. An ultra-low-noise 39-channel amplifier and advanced recording software ("ERPrec") allow the precise recording and storage of up to 37 high-resolution EEG signals. The EEG recording software "ERPrec" has advanced features to apply visual or auditory stimuli (tasks) in order to measure event-related potentials (ERP). "ERPrec" includes standard visual and auditory ERP tasks but also allows the implementation of new individually designed tasks. To connect the EEG system to a computer, an EEG NeuroAmp® II.5s device is used, which also can be utilized as a differential 2-channel amplifier for both, Biofeedback- and Neurofeedback training of various methods (protocols). Besides the modern evidence-based neurofeedback approaches like Othmer "Infra-low" frequency training as well as "Alpha-Theta" and "Synchrony" trainings the "NeuroLab Complete" system also allows neurofeedback training of the "classical" EEG frequency bands and biofeedback HEG training.  To measure physiological parameters for stress and to calculate its level (stress index), the set includes a Combination Sensor. This Biofeedback device enclose four precise low-noise sensors to detect and calculate galvanic skin response (GSR), temperature, heart rate and heart rate variability (HRV) from the skin surface (finger). In order to develop new neurofeedback protocols or expand existing ones, the set includes special interfaces for "BioEra" and "BioExplorer". The set is completed by the "QIKtest CPT" – a computer-independent mobile device to perform visual and/or acoustic continuous performance tests, which is a valuable tool to document the course of therapy.

31.390,00 EURexcl. VAT

All prices excl.possible shipping costs and VAT in the amount of the applicable statutory VAT rate.

The "NeuroLab Complete 31/37" set is aimed at professional researchers and practitioners who are looking for a state-of-the-art and ultra-precise system for both, EEG-/ERP-measurements and Bio-/Neurofeedback training, which comprise of a complete range of equipment and allow a multitude of selection and adjustment options. 

Features:
  • Neurodiagnostic, EEG/ERP research, Biomarker development
  • Comprehensive modern and highly precise EEG and ERP measurement system with 39-channel EEG amplifier for use in neurodiagnostics, EEG-/ERP research, biomarker development and others.
  • Ultra-low-noise EEG amplifier with 39 channels* and socket to connect standard EEG caps with 19/21/31 electrodes. Some extra DIN plugs allow the connection of additional EEG electrodes for GND (ground), A1, A2 and up to six further replacement electrodes.
  • "ERPrec" software, which feature complete control of the EEG amplifier and of EEG/ERP recordings. 
  • "ERP Sync&Input" device, for sensor-based, high-precision acquisition of task presentation timings during ERP recordings. The timing of audio-visual task presentation during ERP measurements is detected by sensors and synchronized with the EEG recording in maximal temporal precision.
  • "ERPrec" software includes standard audio and visual ERP tasks, like "VCPT", "MMN", "TOVA" and others.
  • Additional feature to create new individual ERP tasks
  • EEG/ERP analysis with "WinEEG" software
  • Human Brain Index (HBI) database, a comprehensive collection of normative reference EEG data, which can be used to evaluate the EEG data measured.
  • Impedance meter to individually measure and control the impedances of each of the EEG electrodes. This leads to high-quality measurements of low-noise EEG signals with less artifacts. 
  • Neurofeedback/Biofeedback
  • Complete state-of-the-art set for Neurofeedback
  • Differential EEG amplifier NeuroAmp® II.5s (approved medical device) with impedance meter, sockets for up to 5 electrodes and USB-connectivity. This device can be used as a 1- or 2-channel differential EEG amplifier in infra-low or "classical" frequency neurofeedback training.
  • Neurofeedback software Cygnet® software (approved medical product). In conjunction with an EEG NeuroAmp® II.5s amplifier the Cygnet® software can be used to perform and control neurofeedback and biofeedback training. The software comprises of several modules which feature neurofeedback training in both, the infra-low frequency range and the "classical" EEG frequency bands, respectively. 
  • Additional module "pIRx3" to perform biofeedback hemoencephalography (HEG) training to improve blood circulation in the frontal brain (requires the optional available "pIRx3" sensor).
  • Additional module "Generic Lab" to perform Neurofeedback training with a maximal degree of freedom to select or define a "Reward" and multiple "Inhibit" frequency bands. 
  • Additional module "Tomographic Neurofeedback" which features frequency band training via up to 37 channels at arbitrary filter settings and source-based sLORETA to estimate the location of the neuronal (EEG) generators in the brain.
  • The Cygnet® software include three neurofeedback animations for visual and auditory feedback of the measured EEG brain activity.
  • Additional Brummi tactile feedback device*, which extend the audio-visual Neurofeedback training by the tactile modality.
  • Additional mobile "QIKtest CPT" device to perform computer-independent acoustic and/or visual continuous performance tests, which can be used as a good tool to evaluate and document the course of Neurofeedback training.
  • Additional "pIRx3" device*, which has low-noise amplifiers and three passive infrared-sensors to perform fast and high-accurate temperature radiation measures at the forehead at EEG sites FP1, FP2 and FPz. The device is software-controlled via the "pIRx3" module of the Cygnet® software and this system can be used to perform biofeedback hemoencephalography (HEG) training to improve blood circulation in the frontal brain.
  • Additional Combination Sensor device* for use on a finger to measure and display various parameters of stress, like the skin temperature on a finger, the heart rate, the heart rate variability (HRV) and the galvanic skin response (GSR). By means of these measures a stress index value is calculated and displayed.
  • Interfaces for "BioEra" and "BioExplorer", which allows to develop new neurofeedback protocols or expand existing ones.
  • Sturdy case with foam inlay to safely store all components, which is especially useful when it is required to transport the system, e.g. for home visits.
  • Approved medical product (devices and software) in the European Union
* Device can only be operated in conjunction with an EEG NeuroAmp® II.5s
Technical specifications:
  • View product information: EEG-amplifier NeuroAmp® II5s
  • View product information: 39-channel EEG amplifier (x39)
  • View product information: QIK Test continuous performance tests device*
  • View product information: Brummi tactile feedback device
  • View product information: pIRx3 infrared triple sensor
  • View product information: Combination Sensor Biofeedback device
  • View product information: ERP synchronization- and input device 
Scope of delivery:
  • EEG-amplifier NeuroAmp® II5s
  • USB connection cable (3m) for NeuroAmp® II5s
  • Digital cable 
  • 39-channel EEG amplifier (x39)
  • QIK Test continuous performance tests device
  • USB connection cable (0,5m) for QIk Test
  • Brummi tactile feedback device
  • pIRx3 infrared triple sensor
  • Combination Sensor Biofeedback device
  • Kinesiologie tape (black, 1.2 cm x 5 m)
  • ERP synchronization- and input device 
  • Cygnet® Software (USB Stick containing software and manuals)
  • Frequency Band Training software
  • Tomographic module for Cygnet® software
  • Inner Tube feedback animation (Licence code)
  • Inner Tube feedback animation add-on (Licence code)
  • Dream Scapes feedback animation (Licence code)
  • ERPrec software
  • ERP standard tasks
  • Task generation software
  • Access to collection of normative EEG reference database 
  • BioEra interface
  • BioExplorer interface*
  • Ten20 electrodes paste (4oz tube or jar)
  • Nuprep Skin preparation paste (4oz tube)
  • 1 channel electrodes set with 3 sintered electrodes
  • 2 channel electrodes set with 5 sintered electrodes
  • Jumper
  • Handy case for QEEG device
  • Online initial installation and calibration
*For the analysis and report generation incl. symptomtracking at EEGExpert extra costs will be due.
*Limited functionality